Skip to main content

40LPT

Steel chain with aluminum draw plates

  • APPLICATION TYPE
    Sliding Stroke
    Vertical Stroke

    40LPT
    Main dimensions



    Fixed end position
    deter_A
    deter_B
    deter_C
    deter_D
    deter_E
    Chain length calculation


  • SEPARATION SYSTEM
    Inner vertical separator
    Inner separator with divisor roller

    Vertical Separator

    The vertical separator must be used to manage the inner space and set the proper space for each cable. Standard mounting every second pitch.

    Separatore

    Please input the total quanity needed including
    side separator, if present (in red).

    ALUMINUM DIVISOR ROLLER

    Symmetrical divisor roller

    Separatore : RULLINO
    Divisor roller width: mm
    Suitable for the chain:
    Please input the total quanity needed including
    side separator, if present (in red).
    Vertical Separator

    The vertical separator must be used to manage the inner space and set the proper space for each cable. Standard mounting every second pitch.

    Separatore : S310TCF9
    Please input the total quanity needed including
    side separator, if present (in red).
  • APPLICATION TYPE
    Sliding Stroke
    Vertical Stroke
    MOUNTING POSITION
    Position 1
    Position 2
    Position 3

    STEEL END BRACKET SET

    Steel end bracket set completes both chian ends and allow for fastening on outer radius and inner radius: mounting position must be specified. Stainless steel can be delivered on request.

    End brackets set for
    END BRACKETS
    TIEWRAP CLAMP
    STEEL CABLE CALMP

    The steel cable clamps fasten the cable to the chain
    Open the page

  • APPLICATION TYPE
    Sliding Stroke
    Vertical Stroke
    GUIDE CHANNEL
    SINGLE CHAIN APPLICATION
    DOUBLE OPPOSITE CHAIN APPLICATION
    MATERIAL
    Bright zinc plated
    Stainless steel AISI 304
    Stainless steel AISI 316
    Alluminium

    OPEN GUIDE CHANNEL

    Open guide channels must be used in all sliding applications. They must be installed on radius runway and are availabe in standard length of 2m. Ordering example for 4 meter channel: 4 sidewalls, 4(+1) joining and support sets and if present 4(+1) base profiles.


    A1 = mm; A2 = mm; H1 = mm; H2 = mm; S = mm;

    Gude channel for chain
    GUIDE CHANNEL WITH ROLLERS

    Guide channels with rollers must be used in all sliding applications on the opposite radius runway. Availabe in standard length of 2m. Ordering example for 4 meter channel: 4 sidewalls, 4 rollers sets, 4(+1) joining and support sets and if present 4(+1) base profiles.


    A1 = mm; A2 = mm; H1 = mm; H2 = mm; S = mm;

    Gude channel for chain
    GUIDE CHANNELS WITH POLYDUR BAR

    Guide channels with polydur must be used in all sliding applications on the opposite radius runway. Availabe in standard length of 2m. Ordering example for 4 meter channel: 4 sidewalls, 4 polydur sets, 4(+1) joining and support sets and if present 4(+1) base profiles.


    A1 = mm; A2 = mm; H1 = mm; H2 = mm; S = mm;

    Gude channel for chain
    GUIDE CHANNELS WITH STEEL ANGLE PLATE

    Guide channels with steel angle plate must be used in all sliding applications on the opposite radius runway. Availabe in standard length of 2m. Ordering example for 4 meter channel: 4 sidewalls, 4 angle plate sets, 4(+1) joining and support sets and if present 4(+1) base profiles .


    A1 = mm; A2 = mm; H1 = mm; H2 = mm; S = mm;

    Gude channel for chain
    GROUND CHANNEL

    For the proper functioning of the cable carrier chain, it must rest on a flat surface during its movement. For this purpose, special support channels can be installed along the chain's path. The standard length ranges from 100 mm to 2000 mm, with increments of 100 mm. Upon request, channels up to 3000 mm in length can be provided. In the following fields, please enter the required sector length and the number of necessary sectors.


    A5 = mm; H = mm; S = mm;

    Gude channel for chain
  • BRYLON 6 TECHNICAL DATA

    Norms Properties Units Dry Conditioned
    TERMICHE
    DSC Melting point (10° C/min.) °C    
    ASTM - D 696 Coefficient of linear thermal expansion X10-6 K-1    
    ASTM D 648
    ISO 75
    DIN 53461
    Heat distortion temperature
    ISO 75 1.82 N/mm2 °C 210
    DIN 53461 0.45 N/mm2

    °C
    °C

    210
    220
     
    U. L. 94 Flammability   H.B.  
    IEC 695-2-1 Incandescent wire
    Temperature °C 650
    Thickness
     
    650
    3
     
    FLAMMABILITY
    ASTM-D 257 Volume resistivity Ohm cm 1015 1011
    ASTM-D 257 Surface resistivity Ohm 1013 1011
    ASTM-D 149 Dielectric strength KV/mm 22  
    ASTM-D 150 Dielectric constant (10 Hz) - 3.8 4.5
    ASTM-D 150 Dissipation factor (10Hz) - 0.02 0.09
    PHYSICAL PROPERTIES
    ASTM-D 792 Density g/cm3 1.38  
    ASTM-D 570 Water absorption at 23°C in water for 24 hours % 0.90  
    MECHANICAL PROPERTIES
    ASTM-D 638
    ISO R/527
    DIN 53455
    Tensile yield stress

    Ultimate elongation
    N/mm2

    %
    195

    2.6
    115

    4
    ASTM-D 638
    ISO R/527
    DIN 53457
    Tensile modulus of elasticity N/mm2 10600 6900
    ASTM-D 790
    ISO 178
    DIN 53452
    Flexural strength N/mm2 310 190
    ASTM-D 790
    ISO 178
    Flexural modulus N/mm2 10500 6800
    ASTM-D 256 Unnotched Izod impact strength J/m 140 300
    ISO 180/4C Notched Izod impact strength KJ/m2 110 125
    ASTM-D 785 Rockwell hardness Scala R 122 114

    CHEMICAL RESISTANCE

        BRYLON 6 BRYLON 6 STEEL
    Chemical agents Concentration % Amorphous Crystal  
    Methyl acetate 100 RB3 RB2 RB
    Acetone 100 RB4 RB RB
    Acetic acid (aqueous solution) 40 AF AF AF
    Acetic acid (aqueous solution) 10 AF AF AF
    Acetic acid   AF AF AF
    Citric acid 10 AD 15 RD AD
    Hydrochloric acid (aqueous solution) 36 S S S
    Hydrochloric acid (aqueous solution) 10 AF AF S
    Hydrochloric acid (aqueous solution) 2 AF AD S
    Chromic acid (aqueous solution) 10 AF AF AF
    Chromic acid (aqueous solution) 1 RD RD AF
    Hydrofluoric acid 40 AF AF S
    Formic acid (aqueous solution) 85 S S   AD
    Formic acid (aqueous solution) 40 S AF AF AD
    Phosphoric acid (aqueous solution) 10 AF AF S
    Oleic acid 100 RB3 RB3 RD
    Sulphuric acid 98 S S S
    Sulphuric acid (aqueous solution) 40 AF AF S
    Sulphuric acid (aqueous solution) 10 AF AF S
    Sulphuric acid (aqueous solution) 2 AF AD S
    Tartaric acid (aqueous solution)   RD RB RD
    Water   RB10 RB9 RD
    Chlorine water   RD RD AD
    Ethyl alcohol 96 RD17 RB3 RB
    Ammonia 10 RB11 RB AF
    Petrol 100 RB1 RB RB
    Bitumen   RD RD RB
    Potassium carbonate 100 RB RB AF
    Sodium carbonate 10 RB10 RB3 AF
    Ammonium chloride (aqueous solution) 10 RB RB AF
    Calcium chloride (aqueous solution) 20 S S AF
    Calcium chloride (aqueous solution) 10 RB RB AF
    Sodium chloride 10 RB RB AF
    Formaldehyde (aqueous solution) 30 RD RB AD
    Fat   RB RB RB
    Milk   RB RB RB
    Mercury   RB RB RB
    Oils   RB RB RB
    Oil   RB RB RB
    Paraffin oil   RB RB RB
    Silicon oil   RB RB RB
    Diesel oil   RB RB RB
    Mineral oil   RB RB RB
    Ozone   AF AF AF
    Oil   RB RB RB
    Potassium hydroxide (aqueous solution) 10 RB9 RB3 S
    Sodium hydroxide (aqueous solution) 50 RD RD S
    Sodium hydroxide (aqueous solution) 10 RB5 RB S
    Sodium hydroxide (aqueous solution) 5 RB9 RB S
    Aluminium sulphate 10 RB RB AF
    Soap (aqueous solution)   RB RB RB
    Tincture of iodine   AF AF AD
    Trichloroethylene   RD5 RD4 RB
    Vaseline   RB RB RB

    Legend
    The table shows the resistance to chemical agents of BRYLON 6 and Steel. The number by resistance value side shows which is the % weight increase due to swelling.
    RB - Very good resistance.
    RD - Good resistance.
    AD - Limited resistance.
    AF - Poor resistance.
    S - Soluble.
    Amorphous - Polymer in amorphous state.
    Crystal - Polymer in crystalline state.

PERFORMANCES

Temperature range: -30°C + 125°C


VERTICAL STROKE:
Speed: 0,5 m/s
Acceleration: 2 m/s2