-
APPLICATION TYPE
Main dimensions
Fixed end positionChain length calculation
-
SEPARATION SYSTEM
STRONG HOLD VERTICAL SEPARATORThe strong hold vertical separator that must be used to manage the inner space and set the proper space for each cable. Standard mounting every second pitch.
Please input the total quanity needed including
side separator, if present (in red).Vertical SeparatorThe vertical separator must be used to manage the inner space and set the proper space for each cable. Standard mounting every second pitch.
Please input the total quanity needed including
side separator, if present (in red).ALUMINUM DIVISOR ROLLERSymmetrical divisor roller
Divisor roller width: mm
Suitable for the chain:Please input the total quanity needed including
side separator, if present (in red).STRONG HOLD VERTICAL SEPARATORThe strong hold vertical separator that must be used to manage the inner space and set the proper space for each cable. Standard mounting every second pitch.
Please input the total quanity needed including
side separator, if present (in red).Vertical SeparatorThe vertical separator with central hole must be used to manage the inner space and set the proper space for each cable. Standard mounting every second pitch.
Please input the total quanity needed including
side separator, if present (in red).INNER SEPARATION SYSTEMSeparation system proposed by Brevetti Stendalto, allows the perfect separation and organisation of cables inside the chain, and allows the opening from both inner and outer radius even when the chian is already populated with cables. Many separators in different lengths allow infinite combinations.
SEPARATION SYSTEM WITH 5 HORIZONTAL SEPARATORS
- Side separator
- Mobile intermediate separator
- Vertical separator
- Horizontal Nylon separator - Symmetrical
- Horizontal Aluminium separator - Symmetrical
- Horizontal Nylon separator - Asymmetrical
Vertical Separator S3095FNylon separator for horizontal separator. This offers the option to horizontally divide the space with 5 more horizontal levels.
Please input the total quanity needed including
side separator, if present (in red).Vertical Separator SI309Vertical separator that offers the option to divide the rooms created with the horizontal separators. Suitable for divisions with 5 horizontal separators.
Please input the total quanity needed including
side separator, if present (in red).SIDE SEPARATOR SP3095FNylon side separator for horizontal separator. This offers the option to horizontally divide the space with 5 more horizontal levels.
Please input the total quanity needed including
side separator, if present (in red).HORIZONTAL SYMMETRICAL NYLON SEPARATOR
X = 16 mm
h1 and h2 change with the type of vertical separators and type and quantity of horizontal separators. For their values refers to the picture of the relative vertical separator.
Please input the total quanity needed including
side separator, if present (in red).HORIZONTAL SYMMETRICAL SEPARATOR IN ALUMINIUMHorizontal symmetrical separators allow for multi-level separation on more levels. This separator can be supplied in lengths from 30mm up to 200mm with a width of 1 mm.

X = 0 mm
h1 and h2 change with the type of vertical separators and of the quantity of horizontal separators. For their values refers to the picture of the relative vertical separator.
Please input the total quanity needed including
side separator, if present (in red).HORIZONTAL ASYMMETRICAL NYLON SEPARATORHorizontal asymmetrical separatorors allow the division in levels. The asymmtrical shape allow to get 2mm nore or less respect the SO01. Different space measures are got by a different mounting way.
X = 16 mm
h1 and h2 change with the type of vertical and horizontal separators, along with the way they are mounted. For their values, refer to the picture of the vertical separator adding or subtracting 2 mm.
Please input the total quanity needed including
side separator, if present (in red). -
APPLICATION TYPE
STEEL END BRACKET SETSteel end bracket set completes both ends of the chain and allow its fastening.
-
APPLICATION TYPEGUIDE CHANNELMATERIALBright zinc platedStainless steel AISI 304Stainless steel AISI 316Alluminium
OPEN GUIDE CHANNELOpen guide channels must be used in all sliding applications. They must be installed on radius runway and are availabe in standard length of 2m. Ordering example for 4 meter channel: 4 sidewalls, 4(+1) joining and support sets and if present 4(+1) base profiles.
A1 = mm; A2 = mm; H1 = mm; H2 = mm; S = mm;
Gude channel for chainGUIDE CHANNEL WITH ROLLERSGuide channels with rollers must be used in all sliding applications on the opposite radius runway. Availabe in standard length of 2m. Ordering example for 4 meter channel: 4 sidewalls, 4 rollers sets, 4(+1) joining and support sets and if present 4(+1) base profiles.
A1 = mm; A2 = mm; H1 = mm; H2 = mm; S = mm;
Gude channel for chainGUIDE CHANNELS WITH POLYDUR BARGuide channels with polydur must be used in all sliding applications on the opposite radius runway. Availabe in standard length of 2m. Ordering example for 4 meter channel: 4 sidewalls, 4 polydur sets, 4(+1) joining and support sets and if present 4(+1) base profiles.
A1 = mm; A2 = mm; H1 = mm; H2 = mm; S = mm;
Gude channel for chainGUIDE CHANNELS WITH STEEL ANGLE PLATEGuide channels with steel angle plate must be used in all sliding applications on the opposite radius runway. Availabe in standard length of 2m. Ordering example for 4 meter channel: 4 sidewalls, 4 angle plate sets, 4(+1) joining and support sets and if present 4(+1) base profiles .
A1 = mm; A2 = mm; H1 = mm; H2 = mm; S = mm;
Gude channel for chainGROUND CHANNELFor the proper functioning of the cable carrier chain, it must rest on a flat surface during its movement. For this purpose, special support channels can be installed along the chain's path. The standard length ranges from 100 mm to 2000 mm, with increments of 100 mm. Upon request, channels up to 3000 mm in length can be provided. In the following fields, please enter the required sector length and the number of necessary sectors.
A5 = mm; H = mm; S = mm;
Gude channel for chain BRYLON 6 TECHNICAL DATA
Norms Properties Units Dry Conditioned TERMICHE DSC Melting point (10° C/min.) °C ASTM - D 696 Coefficient of linear thermal expansion X10-6 K-1 ASTM D 648
ISO 75
DIN 53461Heat distortion temperature
ISO 75 1.82 N/mm2 °C 210
DIN 53461 0.45 N/mm2
°C
°C
210
220U. L. 94 Flammability H.B. IEC 695-2-1 Incandescent wire
Temperature °C 650
Thickness
650
3FLAMMABILITY ASTM-D 257 Volume resistivity Ohm cm 1015 1011 ASTM-D 257 Surface resistivity Ohm 1013 1011 ASTM-D 149 Dielectric strength KV/mm 22 ASTM-D 150 Dielectric constant (10 Hz) - 3.8 4.5 ASTM-D 150 Dissipation factor (10Hz) - 0.02 0.09 PHYSICAL PROPERTIES ASTM-D 792 Density g/cm3 1.38 ASTM-D 570 Water absorption at 23°C in water for 24 hours % 0.90 MECHANICAL PROPERTIES ASTM-D 638
ISO R/527
DIN 53455Tensile yield stress
Ultimate elongationN/mm2
%195
2.6115
4ASTM-D 638
ISO R/527
DIN 53457Tensile modulus of elasticity N/mm2 10600 6900 ASTM-D 790
ISO 178
DIN 53452Flexural strength N/mm2 310 190 ASTM-D 790
ISO 178Flexural modulus N/mm2 10500 6800 ASTM-D 256 Unnotched Izod impact strength J/m 140 300 ISO 180/4C Notched Izod impact strength KJ/m2 110 125 ASTM-D 785 Rockwell hardness Scala R 122 114 CHEMICAL RESISTANCE
BRYLON 6 BRYLON 6 STEEL Chemical agents Concentration % Amorphous Crystal Methyl acetate 100 RB3 RB2 RB Acetone 100 RB4 RB RB Acetic acid (aqueous solution) 40 AF AF AF Acetic acid (aqueous solution) 10 AF AF AF Acetic acid AF AF AF Citric acid 10 AD 15 RD AD Hydrochloric acid (aqueous solution) 36 S S S Hydrochloric acid (aqueous solution) 10 AF AF S Hydrochloric acid (aqueous solution) 2 AF AD S Chromic acid (aqueous solution) 10 AF AF AF Chromic acid (aqueous solution) 1 RD RD AF Hydrofluoric acid 40 AF AF S Formic acid (aqueous solution) 85 S S AD Formic acid (aqueous solution) 40 S AF AF AD Phosphoric acid (aqueous solution) 10 AF AF S Oleic acid 100 RB3 RB3 RD Sulphuric acid 98 S S S Sulphuric acid (aqueous solution) 40 AF AF S Sulphuric acid (aqueous solution) 10 AF AF S Sulphuric acid (aqueous solution) 2 AF AD S Tartaric acid (aqueous solution) RD RB RD Water RB10 RB9 RD Chlorine water RD RD AD Ethyl alcohol 96 RD17 RB3 RB Ammonia 10 RB11 RB AF Petrol 100 RB1 RB RB Bitumen RD RD RB Potassium carbonate 100 RB RB AF Sodium carbonate 10 RB10 RB3 AF Ammonium chloride (aqueous solution) 10 RB RB AF Calcium chloride (aqueous solution) 20 S S AF Calcium chloride (aqueous solution) 10 RB RB AF Sodium chloride 10 RB RB AF Formaldehyde (aqueous solution) 30 RD RB AD Fat RB RB RB Milk RB RB RB Mercury RB RB RB Oils RB RB RB Oil RB RB RB Paraffin oil RB RB RB Silicon oil RB RB RB Diesel oil RB RB RB Mineral oil RB RB RB Ozone AF AF AF Oil RB RB RB Potassium hydroxide (aqueous solution) 10 RB9 RB3 S Sodium hydroxide (aqueous solution) 50 RD RD S Sodium hydroxide (aqueous solution) 10 RB5 RB S Sodium hydroxide (aqueous solution) 5 RB9 RB S Aluminium sulphate 10 RB RB AF Soap (aqueous solution) RB RB RB Tincture of iodine AF AF AD Trichloroethylene RD5 RD4 RB Vaseline RB RB RB Legend
The table shows the resistance to chemical agents of BRYLON 6 and Steel. The number by resistance value side shows which is the % weight increase due to swelling.
RB - Very good resistance.
RD - Good resistance.
AD - Limited resistance.
AF - Poor resistance.
S - Soluble.
Amorphous - Polymer in amorphous state.
Crystal - Polymer in crystalline state.




